PostPosted: Sat Sep 17, 2005 5:50 pm    Post subject: coating for 316 steel for use with water Reply with quote

I have a problem with sensor heads (316 steel) they are been used in
drinking water, there is a coating from the water which effects the
sensitivity of the sensor, it takes 3 months for the build up of the scale.
I can clean the sensor head,to correct the problem but we need a solution,

any help appreciated
Brendan Blacklock
Back to top
buut
science forum beginner


Joined: 12 Oct 2005
Posts: 1

PostPosted: Wed Oct 12, 2005 6:08 pm    Post subject: Re: coating for 316 steel for use with water Reply with quote

Eoin Blacklock schreef:

Quote:
I have a problem with sensor heads (316 steel) they are been used in
drinking water, there is a coating from the water which effects the
sensitivity of the sensor, it takes 3 months for the build up of the scale.
I can clean the sensor head,to correct the problem but we need a solution,

any help appreciated
Brendan Blacklock

We are able to coat the SS 316 with PFA or FEP and this must be
sufficient for the probe. llook for www.rhenotherm.de
Best regards,
Ernst
Back to top
Google

Back to top
Display posts from previous:   
Post new topic   Reply to topic Page 1 of 1 [2 Posts] View previous topic :: View next topic
The time now is Tue Dec 12, 2017 6:25 am | All times are GMT
Forum index » Science and Technology » Chem » Coatings
Jump to:  

Similar Topics
Topic Author Forum Replies Last Post
No new posts Estimating the ammount of water relased by burning petrol Jan Kalin Chem 7 Wed Jul 19, 2006 11:26 am
No new posts O-18 Water, surplus Clay Herzog Chem 2 Wed Jul 12, 2006 1:39 pm
No new posts de-ionised water = distilled water = eau déminéralisée ? beerismygas Chem 17 Tue Jul 11, 2006 6:29 pm
No new posts something strange with my water matt_graham13601@yahoo.co Chem 5 Tue Jul 04, 2006 1:51 am
No new posts 5 gallon musical water bottle Glenn Sowell Acoustics 27 Sun Jul 02, 2006 2:22 pm

Copyright © 2004-2005 DeniX Solutions SRL
Other DeniX Solutions sites: Electronics forum |  Medicine forum |  Unix/Linux blog |  Unix/Linux documentation |  Unix/Linux forums  |  send newsletters
 


Powered by phpBB © 2001, 2005 phpBB Group
[ Time: 0.0361s ][ Queries: 16 (0.0217s) ][ GZIP on - Debug on ]